| Product Name | 60A/80A/100A Magnetic Latching Relay for Smart Meter | |||
| P/N | MLLR-2188N | |||
| Maxim switching current |
60A |
80A |
100A |
|
| Maxim switching voltage |
250VAC |
|||
| Maxim switching power | 15,000VA | 20,000VA | 25,000VA | |
| Maxim short circuit current | 2500A 10ms relay can work normally, 4500A 10ms relay dose not burn and explode | |||
| Contact material | AgSnO2 | |||
| Contact resistance | 0.6mΩ Max | |||
| Operate time | 20msec Max | |||
| Release time | 20msec Max | |||
| Insulation Resistance | 1,000 mΩ Min.(DC500V) | |||
| Dielectric strength | Between open contacts | AC2,000V,50/60Hz 1min | ||
| Between oil and contacts | AC4,000V,50/60Hz 1min | |||
| Vibration resistance | Duration | 10~55Hz,double amplitude 1.5mm | ||
| Malfunction | 10~55Hz,double amplitude 1.5mm | |||
| Shock resistance | Duration | 98m/s² | ||
| Malfunction | 980m/s² | |||
| Service life | Electrical life | 100,000 times | ||
| Mechanical life | 10,000 times | |||
| Ambient temperature | -40℃~+85℃(Non-Freezing) | |||
| Weight/ Overall dimension | About 42g | 37.8X30.2X16.5 mm | ||
|
Coil voltage (VDC) |
Resistance ±10% (Ω) |
Closing Voltage |
Release Voltage
|
Rated power (W) |
||
|
Single coil |
Double coil |
Single coil |
Double coil |
|||
|
9 |
54 |
27/27 |
≤70% Rated voltage |
1.5W |
3.0W |
|
|
12 |
96 |
48/48 |
||||
|
24 |
384 |
192/192 |
||||
Switching capability 60A, 80A, 100A
Single and double coil available
Low power consumption
4KV dielectric strength between coil and contacts
UC3/ RoHS compliant