• nybanner

OEM Customized China Good constantia Multilayer Honeycomb Type 100A 0.1 Classis DC Immunis Current Transformer

P/N: MLRH-2147


Product Detail

Product Tags

Scimus nos tantum vigere si nos facile praestamus coniunctos sumptus certae et altae qualitatis commodum simul pro OEM Customised Sinarum Bonum Constantiam Multilayer Honeycomb Type 100A 0.1 Classis DC Immunem Current Transformer, Nostra ordinatio studuit "mos primus " et mandaverunt clientibus adiuvandis negotium parvum augere, ut fiant Magnus Boss !
Scimus nos tantum vigere, si facile coniunctim sumptus certas et magnas utilitates simul praestare possumus.China DC Immunis Current Transformer, Transformer ManufacturerFac te graviter sentire liberum ad nos tua requisita mittere ac discendo tibi respondere incipiemus.Nunc expertam machinationem catervam tenemus ut serviamus pro vestris iustis circa singulas necessitates singulas.Specimina gratuita gratuita in tuo casu mitti possent personaliter ad cognoscendum multo magis notitia.In nisu tuo obviam postulato, fac ut contactum nobiscum serio libenter sentias.Tu nobis electronicas mittes et nos directe contact.Praeterea gratae sunt visitationes officinae nostrae e globo circumcirca, multo melius nostrae organizationis cognoscendae.cce res.In mercatura nostra cum mercatoribus multarum regionum, plerumque aequalitatis et mutui utilitatis principium adhaeremus.Profecto spes nostra est mercatus, communibus conatibus, commercia quaeque et amicitia ad mutuam utilitatem nostram.Expectamus percontationes tuas questus.

Descriptio

Product Name Aula Effectum Current Sensor Split Core Transducer
P/N MLRH-2147
Primae Rated Current 20/50/100/200A/300A/400A
Output intentione Una potentia 2.5±2V
Dual Power Dual Power 0±4V
Nulla sustinere voltage 3KV/1min
Operating Frequency 50-60Hz
Operating Temperature -40℃ ~ +85℃
Insulation Epoxy resinae encapsulatae
Exterior Casus Flamma retardant PBT
Aapplication Variabilis frequentia electrica adjumenta inverter AC/DC variabilis-celeritate driveSwitched Mode Power Supplies (SMPS)

Features

Securus institutionem

Fenestra structura

Humilis potentia consummatio valde bona linearity

Solum unum consilium late current ratings range

Maximum immunitatis externae impedimentum

Damna nulla insertio

Dual Power Aula Current Sensor

Electrical data (Ta=25ºC±5ºC)

Rated input IPN 20/50/100 A
range mensuræ IP ±30/±75/±150 A
Output voltage Vo ±4.0*(IP/IPN) V
Onus resistentia RL >10
Copia voltage VC ±12 ~±15)±5% V
Sagacitas XG @IPN,T=25°C <±1.0 %
Offset voltage VOE @IP=0,T=25°C <±25 mV
Temperatura variatio VOE VOT @IP=0,-40 ~ +85°C <±1.0/< ±0.5/< ±0.5 mV/℃
Temperatura variatio VO VOS @IP=IPN,-40 ~ +85°C <±2.5 %
Hysteresis offset voltage VOH @IP=0, post 1*IPN <±25 mV
Linearity error ε < 1.0 %FS
di/dt > 100 A/μs
Responsio tempus tra @90% of IPN <5.0 μs
Potentia consummatio IC @+15V <23 mA
@-15V <4.5 mA
Bandwidth BW @-3dB,IPN DC-20 KHZ
Nulla voltage Vd @50/60Hz, 1min, AC ,1.5mA 4.0 KV

 

Ring Type Electrical data:(Ta=25°C,Vc=+12.0VDC,RL=2KΩ)

Parameter

MLRH-50A/2V

MLRH-100A/2V

MLRH-200A/2V

MLRH-300A/2V

MLRH-400A/2V

Unitas

Rated input

IPN

50

100

200

300

400

A

range mensuræ

IP

0~±50

0~±100

0~±200

0~±300

0~±400

A

Output voltage

Vo

2.500±2.0*(IP/IPN)

V

Output voltage

Vo

@IP=0,T=25°C

2.500

V

Onus resistentia

RL

>2

Copia voltage

VC

+12.0 ±5%

V

Sagacitas

XG

@IPN,T=25°C

<±1.0

%

Offset voltage

VOE

@IP=0,T=25°C

<±25

mV

Temperatura variatio VOE

VOT

@IP=0,-40 ~ +85°C

<±1.0

mV/℃

Hysteresis offset voltage

VOH

@IP=0, post 1*IPN

<±20

mV

Linearity error

ε

< 1.0

%FS

di/dt

> 100

A/µs

Responsio tempus

tra

@ XC% of IPN < 3.0

µs

Potentia consummatio

IC

15

mA

Bandwidth

BW

@-3dB,IPN

DC-20

KHZ

Nulla voltage

Vd

@50/60Hz, 1min,AC

2.5

KV

Generalis notitia

Parameter

Symbol

Value

Unit

Operating Temperature

TA

-40 ~ +85

°C

Repono temperatus

Ts

-55~ +125

°C

Pondus

m

70

g

materia plastica

PBT G30/G15,UL94- V0;

Signa

IEC60950-1:2001

EN50178:1998

SJ20790-2000

 

Dimensiones (mm);

222

Dicta

1, Cum current mensurabitur per clavum primum sensoris, intentione in output fine mensurabitur.(Nota: Falsa wiring inveniatur in damno sensori).

2, Custom design in the different rated input current and output voltage are available.

3. Operatio dynamica est optima, si prima foraminis plene impletur;

4, Ductor primarius sit <100°C;

 

8

Rectangularis Type Electrical data:(Ta=25°C,Vc=+12.0VDC,RL=2KΩ)

Parameter

MLRH-200A/2V

MLRH4-600A/2V

MLRH4-800A/2V

MLRH4-1000A/2V

MLRH4-1200A/2V

MLRH4-2000A/2V

Unitas

Rated input

IPN

200

600

800

1000

1200

2000

A

range mensuræ

IP

0~±200

0~±600

0~±800

0~±1000

0~±1200

0~±2000

A

Output voltage

Vo

2.500±2.0*(IP/IPN)

V

Output voltage

Vo

@IP=0,T=25°C

2.500

V

Onus resistentia

RL

>2

Copia voltage

VC

+12.0±5%

V

Sagacitas

XG

@IPN,T=25°C

<±1.0

%

Offset voltage

VOE

@IP=0,T=25°C

<±25

mV

Temperatura variatio VOE

SUFFRAGIUM

@IP=0,-40 ~ +85°C

<±1.0

mV/℃

Hysteresis offset voltage

VOH

@IP=0, post 1*IPN

<±20

mV

Linearity error

ε

< 1.0

%FS

di/dt

> 100

A/µs

Responsio tempus

tra

@ XC% of IPN < 7.0

µs

Potentia consummatio

IC

15

mA

Bandwidth

BW

@-3dB,IPN

DC-20

KHZ

Nulla voltage

Vd

@50/60Hz, 1min,AC

6.0

KV

 

Generalis notitia

Parameter

Symbol

Value

Unit

Operating Temperature

TA

-40 ~ +85

°C

Repono temperatus

Ts

-55~ +125

°C

Pondus

m

200

g

materia plastica

PBT G30/G15,UL94- V0;

Signa

IEC60950-1:2001

EN50178:1998

SJ20790-2000

 

Dimensiones (mm);

111

Dicta

1, Cum mensura currenti percurrit primum clavum sensoris, voltatio erit

In fine metiri (Nota: Falsa wiring inveniatur in damno sensoris).

2, Consuetudo designationis in diversis input currentibus aestimata et output intentione prompta sunt.

III, dynamica perficientur optima est prima foraminis si plene impletur;

4, Ductor primarius sit <100°C;

10Scimus nos tantum vigere si nos facile praestamus coniunctos sumptus certae et altae qualitatis commodum simul pro OEM Customised Sinarum Bonum Constantiam Multilayer Honeycomb Type 100A 0.1 Classis DC Immunem Current Transformer, Nostra ordinatio studuit "mos primus " et mandaverunt clientibus adiuvandis negotium parvum augere, ut fiant Magnus Boss !
Altera nativusChina DC Immunis Current Transformer, Transformer ManufacturerFac te graviter sentire liberum ad nos tua requisita mittere ac discendo tibi respondere incipiemus.Nunc expertam machinationem catervam tenemus ut serviamus pro vestris iustis circa singulas necessitates singulas.Specimina gratuita gratuita in tuo casu mitti possent personaliter ad cognoscendum multo magis notitia.In nisu tuo obviam postulato, fac ut contactum nobiscum serio libenter sentias.Tu nobis electronicas mittes et nos directe contact.Praeterea gratae sunt visitationes officinae nostrae e globo circumcirca, multo melius nostrae organizationis cognoscendae.cce res.In mercatura nostra cum mercatoribus multarum regionum, plerumque aequalitatis et mutui utilitatis principium adhaeremus.Profecto spes nostra est mercatus, communibus conatibus, commercia quaeque et amicitia ad mutuam utilitatem nostram.Expectamus percontationes tuas questus.


  • Previous:
  • Deinde:

  • Epistulam tuam hic scribe et mitte nobis